Gold Member Since 2007
Audited Supplier
Guangdong Honny Power-Tech Co., Ltd.

Gas Generator, CHP, Cchp manufacturer / supplier in China, offering 200kw-2000kw CHP Cchp Gas Cogeneration Generator Power Plant, 320kw 400kVA Engine Ntaa855 G7a Cummins Genset, 260kw / 325kVA Googol Soundproof / Silent Diesel Generator Set and so on.

(/ )

Supplier Homepage Product Gas generators 200kw-2000kw CHP Cchp Gas Cogeneration Generator Power Plant

200kw-2000kw CHP Cchp Gas Cogeneration Generator Power Plant

FOB Price: US $10,000-500,000 / Piece
Min. Order: 1 Piece
Min. Order FOB Price
1 Piece US $10,000-500,000/ Piece
Get Latest Price
Production Capacity: 5 PCS/Month
Transport Package: Plastic Film Package, or as Need
Payment Terms: L/C, T/T

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: CHP CCHP
  • Certification: CE, TLC, ISO, CCC
  • Standard: Standard
  • Fuel: Natural Gas / Bio-Gas/ Dual Gas
  • Controller: Deif, Comap, Deepsea ,etc
  • Air Ratio: 1.6-1.7
  • Speed & Frequency: 50/60Hz,1000/1200/1500/1800rpm
  • Model Option: Silent Canopy, CHP, Cchp, Remote Radiator
  • Specification: ISO8528
  • HS Code: 8502120000
  • Gas Source: Gas
  • Power: >200kW
  • Gas Engine: Googol J , R Series
  • Alternator: Marathon, Stamford, Leroy Somer, Engga
  • Ignition System: German Motortech
  • Generator Electric Effieicncy: 36-40%
  • Generator Power Range: 200kw-200kw
  • Trademark: HONNY POWER
  • Origin: Donguan, Guangdong, China
Product Description
200kw-2000kw CHP CCHP Gas Cogeneration Generator Power Plant

Applied gas:
Natural Gas, Biogas, City Sewage Gas, Landfill gas, Oil gas, farm biogas, Coal mine gas, etc
Acceptable fuel gas pressure: 5~12kPa
CH4 content: For natural gas≥ 85% CH4, content: For biogas≥ 40%
Gas heat value≥ 5500kcal/Nm3 (23MJ/Nm3 ). Genset output power will increase as the gas heat value increase, if use low heat value gas for fuel (Heat value<5500kcal/Nm3, it will lower the power efficiency.
Gas doesn't include free water or free materials (the size of impurities should be less than 5μ M. )
H2S content≤ 200mg/Nm³
NH3 content≤ 20mg/Nm³
Impurities content≤ 30mg/Nm³ ; Size≤ 5μ M
Water content≤ 40g/Nm³ , no free water.

Acceptable working conditions:
Ambient temperature: -10° C~+40° C
(antifreeze or preheater needed for below 0° C)
Relative humidity: <90%(20° C)
Altitude: ≤ 1000m
Normal working conditions:
Genset can run at rated power on the conditions:
Atmospheric Pressure: 100kPa, Ambient Temp: 20° C, Relative Humidity: 30%.


Standard Scope of Supply:
1. Brand new gas engine, 90% parts include engine body, crank shaft, cam shaft, piston, cylinder head, etc made by US Googol with best quality
2. Brand new brushless France Meccalte, Leroy Somer, Stamford alternator
3. Rating: 3 phases 4 lines. 400/230V, 50 HZ, 1500rpm, 0.8PF, IP22-23, Insulation class H (60Hz 1200RPM option)

4. Radiator for 40° C/50° C ambient temperature
5. Ignition system adopted Germany Motortech
6. Emergency stop mounted
7. Battery, Battery cable and Battery charger
8. Standard tool box

9. Standard Accessory for installation (include bellows, silencer, flange, asbestos pad, Anti-rust water, screw )
10. Gas Train include Regulator valve, Electromagnetic Valve, Fire arrestor, Ball Valve (Chinese brand)


The range for the module CHP:
1. CHP unit
Engine designed to work on biogas and a synchronous generator that allows parallel operation of power grid. Unit can operate continuously with load from 50% to 100% nominal power.
2. Container - enabling the reduction the level of noise to 65 dB - distance 10m.
3. Process heat units - exchangers system with the necessary piping, valves, circulation pumps and automatic control system with the task of receiving heat from the cooling unit (lubricating oil, cooling mixture, the engine block) and flue gas and transfer it to the water heater.
4. Emergency cooling system with radiator - the purpose is to remove the heat from the cooling unit. Control of the cooler will be Executed by automatic control unit of the CHP.
5. Cooling unit of air - fuel - with the purpose of removal of heat resulting from compressing a mixture of air and gas and precipitated it on the radiator. Control of the radiator will be done automatically from the control unit of the CHP.
6. Ventilation system -
providing the required amount of air supply (air fan,temperature sensor, acoustic silencers) for the combustion and heat removal emitted by the radiation unit.
7. Lubrication system -leading to aggregate the required amount of oil (oil pump, steering pump oil) together with the fresh oil tank.
8. Gas supply line - the security and control system of biogas pressure (safety valve, set of valves electromagnetic sensors, pressure regulator zero pressure),
9. Flue gas installation - the chimney, bypass of the exhaust and silencer on the exhaust
10. Active gas detection system - gas sensor inside the container with the shut-off valve on the line biogas in a cabinet on the wall of the container.
11. Supply and installation of cabinets HAS - Control Module synchronization and security to work with the power grid, executing the following security features:
 under-and over frequency
 under-and over voltage
 Network synchronization and monitoring of the generator,
 Adjustable output power when excessive temperature of the intake air,
 Control of auxiliary drives, pumps cooling circuit shunt unit, cooling fan module and Shutter outside air and heat recovery from the air ejector, control devices for grease injection, speed control, fuel injection, gas installation, battery charger, start,

  US Googol Gas Generators
Genset Model
HGGM160HGGM200HGGM300HGGM360HGGM500HGGM800HGGM1200HGGM1500
Engine Model
RTA780G1RTA890G1RTA1120G1RTA1340G1JTA2160G1JTA3240G1JTA4320G1JTA5400G1
Speed rpm15001500150015001500150015001500
Frequency Hz5050505050505050
Generator Output (COP)kW160 200 300 360 500 800 1200 1500 
Typical  Generator Efficiency 
93.5%94.0%94.5%95.0%95.0%95.5%95.8%96.0%
Power Factor
0.80.80.80.80.80.80.80.8
Engine Output  (COP)kW195 235 348 410 600 890 1315 1708 
BMEP for Continually Outputbar9.36 14.50 14.50 15.30 12.98 11.48 14.20 13.56 
Engine Parameter








Configuration
In lineVeeVeeVeeVeeVeeVeeVee
No. of Cylinders
6810128121620
Displacement l12.814.618.321.935.453.170.888.5
Bore mm128128128128170170170170
Stroke mm166142142142195195195195
Compression Ratio
121:112:112:112:112:112:112:112:1
Piston Speed m/s8.37.17.17.19.759.759.759.75
Static Speed Droop 
≤  5%≤  5%≤  5%≤  5%≤  5%≤  5%≤  5%≤  5%
Number of Flywheel Teeth 
160 160 160 160 218 218 218 218 
Flywheel House Size
SAE1-14SAE1-14SAE1-14SAE1-14SAE00-18SAE00-21SAE00-21SAE00-21
System Parameter








Lube Oil Specification
API-CF4API-CF4API-CF4API-CF4API-CF4API-CF4API-CF4API-CF4
Oil Capacity l40324045160180240300
Max. Premissiable Oil Temperature °C110110110110110110110110
Oil Pressure Warning kPa200 200 200 200 300 300 300 300 
Oil Pressure Shutdown kPa160 160 160 160 200 200 200 200 
Coolant Capacity for Engine l1820212370100140200
Max. Prenissiable Temperature  °C9090909082828282
Max. Coolant Warning Temperature  °C9595959585858585
Max. Coolant Shutdown Temperature  °C10510510510590909090
Thermostat Open Temperature °C8271717171717171
Flow of Coolant pump m³/h19.72626262*432*492*492*60
Max. Intake Restriction KPa22222222
Max. Exhaust Temperature°C580580580580580580580580
Max. Exhaust Back PressureKpa22222222
Exhaust Flange Diameter mm1*1252*1002*1002*1001*2501*2502*2502*250
Charging Alternator Capacity A3535353555555555
Starting Voltage V2424242424242424
Thermal Balance








Electrical PowerkW160 200 300360500 800 1200 1500 
Thermal Output± 8% kW164 205 311 378 538 830 1232 1518 
Electrical Efficiency %404040404040.540.941
Thermal Efficiency %414141.54243424241.5
Total Efficiency%818181.5828382.582.982.5
Genset Dimension








Length mm31003300350036004600510060006500
Width mm13001500150015002190219026002600
Height mm15001800180018002300260027002800
Genset Weightkg2500350039004100700090001320017500
200kw-2000kw CHP Cchp Gas Cogeneration Generator Power Plant
200kw-2000kw CHP Cchp Gas Cogeneration Generator Power Plant
Send your message to this supplier
Avatar
Mr. Bruce Cui
General Manager
*From:
To: Mr. Bruce Cui
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now