Gold Member Since 2007
Audited Supplier
Guangdong Honny Power-Tech Co., Ltd.

Generator Powerhouse, 2MW Power Plant, MW Power Plant manufacturer / supplier in China, offering Large Electricity Supplier 2MW Diesel Generator Powerhouse, Large Horsepower Electric Injection Diesel Generators, 50Hz Googol Engine High Voltage Diesel Genset with Engga Leroy Somer and so on.

(/ )

Supplier Homepage Product Googol Generators Large Electricity Supplier 2MW Diesel Generator Powerhouse

Large Electricity Supplier 2MW Diesel Generator Powerhouse

FOB Price: US $300,000-310,000 / Set
Min. Order: 1 Set
Min. Order FOB Price
1 Set US $300,000-310,000/ Set
Get Latest Price
Port: Shenzhen, China
Production Capacity: 100PCS/Month
Payment Terms: L/C, T/T

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: HGM2750
  • Installation Method: Fixed
  • Cooling Method: Water Cooling
  • Speed: Speed
  • Usage: Common Units
  • Excitation Mode: AC Rotating Exciter
  • Alternator Model: Meccalte Eco46-2L/4
  • Voltages: Low Voltage 380V , 400V ,Adjustable
  • Warranty: 1 Year or 1000 Working Hours
  • Canopy Types: Silent ,Container,Trailer ,etc
  • Lowest Fuel Consumption Ratio: 191.75g/Kw.Hr
  • Transport Package: Poly Plastic Firm/ Wooden Package
  • Origin: Guangdong, China
  • Type: Self-Starting Diesel Generator
  • Stroke: Four Stroke
  • Output Type: AC Three Phase
  • Conditions of Use: Land Use
  • Landuse Type of Unit: Low Noise
  • Engine Model: Googol Qta5400g1 Engine
  • Controller Model: Deep Sea, Comp, Datakom , etc
  • Certificates: CE,ISO.BV,GOST,TUV,SGS,etc
  • Prime Power: 2000kw 2500kVA
  • Option: ATS,Circuit Breaker,Parallel, Remote Controlpanels
  • Trademark: HONNY
  • Specification: ISO8528, CE, GOST, etc
  • HS Code: 8502131000
Product Description
Large Electricity Supplier 2MW Diesel Generator Powerhouse


Supply Scope:
Generator, LV & HV distribution, installation & commission engineering

Main Supplying:
. Generator
. Cooling system
. Fuel filter & dealing system
. Lube oil system
. Gas collection and dealing system
. Black start system

Performance Feature
Engine and alternator shall be mounted on a same frame steel skid.
Built-in damper for anti-vibration.
World most famous brand diesel engine.
World famous brand AC alternator.
Advanced and reliable control module
Full range protection function and alarm shutdown feature.

Alternator Feature
Brush-less, 4 poles, rotation magnet.
IP21-23(NEMA1) enclosure is standard for all industrial alternators.
The insulation system is Class H
Simple installation and maintenance, with easy access to terminals, rotating diodes and coupling bolts.
Wide range of flange adaptors and single bearing disc coupling.
Standard 2/3 pitch windings avoid excessive neutral currents
AVR auto voltage regulator, auto exciter, auto adjustment

Standard Accessory
Common steel base frame, Damper, Exhaust silencer, Flexible pipe, Battery and connecting wires, Operation manual and document.

Optional Accessory
Engine coolant and oil heater, Alternator space heater, Cooling for heat exchanger, Control system with RS232/485 communication interface, Battery charger by main supply, Fuel-water separator, Daily fuel tank, ATS & paralleling system, and Moving Trailer.

Silent Canopy Description
Standard Accessory:
Steel Weatherproof Canopy
Built In Fuel Tank For 8 Hours Running
Built In Control Panel
Built In Start Battery
Power Output Rapid Insert
Windows for Looking
Air Louver for Intake & Exhaust
Exhaust Gas Silencer
Soundproof Type

Quality Warranty Period:
All equipment is guaranteed for a period of 1000 hours running or 12 months from the date when the generator set has been delivered from the factory.

ATS SYSTEM
For emergency power usage in building, Auto transfer switch (ATS) is essential. ATS can automatic transfer load from Mains power supplying to Emergency power. In normal, when the Main power supplying failure or voltage drop below 80% of normal voltage, ATS will auto start Emergency generator set after a preset time of 0-10 sec (adjustable according to the users). Once generator reach at rated speed, the ATS will transfer the load to emergency generator sets automatically
Standard Accessory Battery4X200AH 12V
Battery Wires1 set
Flexible Pipe10*2 inch
Industry Silencer10*2 inch
Optional Accessory5VCB Breaker Panel 
Fuel Tank2000 Liter
Fuel-water Separator  
HeaterCoolant & Oil Heater
Generator ModelHGM2750
Genset Prime Power2000kW/2500kVA
 
Engine Ratings:
Engine Speed( RPM )1500
Generator set Frequency( Hz )50
Engine Standby Power (LTP)( kW )2280 
Engine Prime Power (PRP)( kW )2073 
Engine Continuous Power (COP)( kW )1700 
Typical Generation Prime Output  ( kVA )2500
Typical Generation Prime Output  ( kW )2000
 
Basic Performance Datasheet
Aspiration Type  Turbocharge r , air-water After -  cooler
Turbocharger Type 2 *R151
Injection Type Direct Injection
Configuration Vee
No. of Cylinders 20
Displacement( liters )88.5
Bore( mm )170
Stroke( mm )195
Compression Ratio 13.5:1
Piston Speed( m/s )9.75
Rotation Direction (from flywheel) Counter Clockwise
Number of Flywheel Teeth 218
Flywheel House Size SAE00-21
 
Fuel System
Governor Type Electrical Control
Engine Output at generator set prime output( kW )2073 
Fuel Consumption at 25% of generator set prime output( l/h )147.93 
Fuel Consumption at 50% of generator set prime output( l/h )245.85 
Fuel Consumption at 75% of generator set prime output( l/h )318.85 
Fuel Consumption at 100% of   generator set prime output( l/h )476.98 
Lowest Fuel Consumption Ratiog/kW.hr191.75 
 
Engine Dimension
Length( mm )4110
Width( mm )1459
Height( mm )1820
Engine Dry Weight w/o Cooling System( kg )7600

Large Electricity Supplier 2MW Diesel Generator Powerhouse
 
Send your message to this supplier
Avatar
Mr. Bruce Cui
General Manager
*From:
To: Mr. Bruce Cui
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now