Gold Member Since 2007
Audited Supplier
Guangdong Honny Power-Tech Co., Ltd.

Biogas Generator, 720kw Gas Generator, 900kva Gas Generator manufacturer / supplier in China, offering 720kw 900kVA Biogas Electric Power Generator Set, 50Hz Googol P Series Marine Diesel Engine 330kw-800kw, Googol Large Power Engine 800kw /1000kVA Diesel Generator Set and so on.

(/ )

Supplier Homepage Product Gas generators 720kw 900kVA Biogas Electric Power Generator Set

720kw 900kVA Biogas Electric Power Generator Set

FOB Price: US $220,000-240,000 / Set
Min. Order: 1 Set
Min. Order FOB Price
1 Set US $220,000-240,000/ Set
Get Latest Price
Production Capacity: 5 PCS/Month
Transport Package: Plastic Film Package, or as Need
Payment Terms: L/C, T/T

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: HGGM900
  • Certification: CE, ISO
  • Standard: Standard
  • Fuel: Natural Gas / Bio-Gas/ Dual Gas
  • Start: Electric Start
  • Engine Standard: ISO8528, ISO3046
  • Rated Voltage: Low or High Voltage
  • Engine Model: Googol Jta2160
  • Specification: ISO8528
  • HS Code: 8502120000
  • Gas Source: Gas
  • Power: >200kW
  • Usage: Generator Set, G-Drive
  • Cylinder: V8 Cylinder in Line
  • Cold Style: Water-Cooled or CHP Cchp Use
  • Alternator Standard: Bs5000, VDE0530, NEMA Mg1-32, IEC34
  • Power Output: 720kw 900kVA
  • Trademark: HONNY POWER
  • Origin: Donguan, Guangdong, China
Product Description
720kW 900kVA BioGas Electric Power Generator set
CH4: 60%, CO2: 40%

Applied gas:
Natural Gas, Biogas, City Sewage Gas, Landfill gas, Oil gas, farm biogas, Coal mine gas, etc
Acceptable fuel gas pressure: 5~12kPa
CH4 content: For natural gas≥ 85% CH4, content: For biogas≥ 40%
Gas heat value≥ 5500kcal/Nm3 (23MJ/Nm3 ). Genset output power will increase as the gas heat value increase, if use low heat value gas for fuel (Heat value<5500kcal/Nm3, it will lower the power efficiency.
Gas doesn't include free water or free materials (the size of impurities should be less than 5μ M. )
H2S content≤ 200mg/Nm³
NH3 content≤ 20mg/Nm³
Impurities content≤ 30mg/Nm³ ; Size≤ 5μ M
Water content≤ 40g/Nm³ , no free water.

Acceptable working conditions:
Ambient temperature: -10° C~+40° C
(antifreeze or preheater needed for below 0° C)
Relative humidity: <90%(20° C)
Altitude: ≤ 1000m
Normal working conditions:
Genset can run at rated power on the conditions:
Atmospheric Pressure: 100kPa, Ambient Temp: 20° C, Relative Humidity: 30%.

Standard Scope of Supply:
1. Brand new gas engine, 90% parts include engine body, crank shaft, cam shaft, piston, cylinder head, etc made by US Googol with best quality
2. Brand new brushless France Meccalte, Leroy Somer, Stamford alternator
3. Rating: 3 phases 4 lines. 400/230V, 50 Hz, 1500rpm, 0.8PF, IP22-23, Insulation class H (60Hz 1200RPM option)
4. Radiator for 40° C/50° C ambient temperature
5. Ignition system adopted Germany Motortech
6. Emergency stop mounted
7. Battery, Battery cable and Battery charger
8. Standard tool box
9. Standard Accessory for installation (include bellows, silencer, flange, asbestos pad, Anti-rust water, screw )
10. Gas Train include Regulator valve, Electromagnetic Valve, Fire arrestor, Ball Valve (Chinese brand)

Optional:
1. Sound-proof / Container canopy
2. CHP & CCHP system
3. Grid parallel system
4. Remote radiator or horizontal type radiator
5. Auto oil filling system
6. Water heater
7. Oil heater
8. Gas leaking detector
9. Flame detector
10. Gas scrubber

The gas generators are extremely flexible, cost efficient and meet the growing trend towards the use of natural gas for power generation. This is driven by liquid fuel cost, emissions legislation and noise concerns. Natural gas is becoming much more widely available through pipelines and LNG terminals.

Gas generator key benefits
Cost-effective power generation
Flexibility to quickly ramp power supply up or down
Exceptional performance and reliability
Reduced environmental impact
Combined heat and power provision
24/7, turn-key service

Reduced environmental impact
Honny Power natural gas generators adopt Googol brand gas engines. The proven 'lean burn ' gas engine technology origin from USA. These heavy-duty, spark-arrested, turbo-charged, after-cooled engines have a purpose built alternator which is suitable for continuous operation in hash environments. The patented fuel system and advanced engine design ensure emission regulations are met as they are highly efficient with a virtually smoke free operation.
Compared to diesel generators, gas generators have a much lower sulphur, NOx and greenhouse gas emission content.

Combined Heat and Power (CHP) benefits
Honny Power gas power solution allows customers to use heat generated by the natural gas powered units, to produce hot water for the customers own CHP units. This can be vital in many processing environments in creating added saving for the customer. This facility supports combined heat and power
Strategies, without the need for long term capital investment in new plant.

An alternative energy source
Gas generators are an alternative energy source, which can provide cheaper, more flexible electricity for companies that may be paying a high price for fixed electricity tariffs.
Genset Model   HGGM900
Engine Model   JTA2160G3
Rating Speed  rpm 1500
Frequency  Hz 50
Generator Output (COP) kW 720 
Power Factor   0.8
Gas Engine Parameter    
Engine Output  (COP) kW 751 
Air Ratio λ 1.7 
Configuration   8 Vee
Displacement  l 35.4
Bore  mm 170
Stroke  mm 195
Compression Ratio   12:1
Piston Speed  m/s 9.75
Number of Flywheel Teeth    218 
Flywheel House Size   SAE00-18
System Parameter    
Oil Capacity  l 160
Max. Allowed Oil Temperature  °C 110
Oil Pressure Warning  kPa 300 
Oil Pressure Shutdown  kPa 200 
Coolant Capacity for Engine  l 70
Max. Coolant Warning Temperature   °C 95
Max. Coolant Shutdown Temperature   °C 100
Max. Intercooler Outlet Temperature   °C 40.5
Flow of Coolant pump (JW) m³/h 48
Flow of Coolant pump (LT) m³/h 45
Max. Exhaust Temperature °C 485
Exhaust Flow kg/h 3896
Exhaust Flange Diameter  mm 1*250
Charging Alternator Capacity  A 55
Starting Voltage  V 24
Thermal Balance    
JW Coolant Heat  ± 8% kW 375
CAC Intercooler Heat ± 8% kW 60
Exhaust Heat up to 120°C ± 8% kW 434
Energy Input  kW 1823 
ELectrical Efficiency  % 39.5 
Mechanical Efficiency  % 41.2 
Thermal Efficiency % 44.4 
Total Efficiency % 83.9 
Gas Consumption MJ/kWh 9.11 
Generator Parameter-MECC ALTE    
Generator Model   ECO43-1LN/4
Generator Prime Output kW 880
Generator Efficiency @ 0.8PF   95.9%
Genset Dimension    
Length  mm 4600
Width  mm 2190
Height  mm 2300
Genset Weight kg 7650

Send your message to this supplier
Avatar
Mr. Bruce Cui
General Manager
*From:
To: Mr. Bruce Cui
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now